CHS 914/20

Production class: hot finished (EN 10210-2)

Section geometry

CHS shape
Diameter (D):
914mm
Wall thickness (t):
20mm

Section properties

Moment of inertia (I):mm⁴
Y-axis:
5.615E9
Z-axis:
5.615E9
Elastic section modulus (Wel):mm³
Y-axis:
1.229E7
Z-axis:
1.229E7
Plastic section modulus (Wpl):mm³
Y-axis:
1.599E7
Z-axis:
1.599E7
Radius of gyration (i):mm
Y-axis:
316.2
Z-axis:
316.2
Plastic shear area (Av):mm²
Y-axis:
35760
Z-axis:
35760

Weight per meter:
440.9kg/m
Area (A):
56170mm²
Surface area per meter:
2.871m²/m
Torsion constant (It):
1.123E10mm⁴

Profile overview for CHS 914/20

The CHS 914/20 is a structural steel cross-section utilized in commercial construction, industrial framing, and mechanical engineering. Manufactured as a hot finished section, it complies with EN 10210-2 dimensional standards, ensuring predictability in detailing and fabrication.Access to its exact geometric and statical properties is essential for 3D modeling and structural verification.

Geometry: This circular hollow section features a nominal outer diameter of 914 mm and a uniform wall thickness of 20 mm. With a cross-sectional area of 56171.67665 mm² and a linear mass of 440.9476617 kg/m, the CHS 914/20 offers a distinct stiffness-to-weight ratio for both column (axial) and beam applications.

Section properties: For design of bending, the major and minor axis properties dictate the member's structural capacity. The strong-axis moment of inertia (Iy) of 5614611853 mm⁴ governs major deflection and serviceability limits. To calculate the ultimate bending resistance, engineers may utilize the strong-axis plastic section modulus of 15987386.67 mm³. For lateral stability and column buckling verifications, the weak-axis moment of inertia (Iz) provides 5614611853 mm⁴ of lateral stiffness.

Advanced analysis: For complex load cases, the CHS 914/20 provides a y-axis shear area (at strong bending axis) of 35760 mm² for web shear verification and a torsion constant of 11229223707 mm⁴ for calculating rotational twist under eccentric loading.