RHS 200x120/5

Production class: cold formed (EN 10219-2)

Section geometry

RHS shape
Height (h):
200mm
Width (b):
120mm
Wall thickness (t):
5mm
Outer rounding (router):
10mm
Inner rounding (rinner):
5mm

Section properties

Moment of inertia (I):mm⁴
Y-axis:
1.649E7
Z-axis:
7.501E6
Elastic section modulus (Wel):mm³
Y-axis:
1.649E5
Z-axis:
1.250E5
Plastic section modulus (Wpl):mm³
Y-axis:
2.009E5
Z-axis:
1.414E5
Radius of gyration (i):mm
Y-axis:
73.7
Z-axis:
49.71
Plastic shear area (Av):mm²
Y-axis:
1138
Z-axis:
1897

Weight per meter:
23.83kg/m
Area (A):
3036mm²
Surface area per meter:
0.6228m²/m
Torsion constant (It):
1.652E7mm⁴

Verify RHS 200x120/5 in Eurocode 3 calculators

Pre-load this cross-section directly into a structural analysis or individual capacity check.

Member design & optimization

Simple supported beam with permanent & variable load

Configure span length and manual point (F at midspan) or distributed (q from 0 to L) loads.

mm
kN/m
kN/m

Profile overview for RHS 200x120/5

The RHS 200x120/5 is a structural steel cross-section utilized in commercial construction, industrial framing, and mechanical engineering. Manufactured as a cold formed section, it complies with EN 10219-2 dimensional standards, ensuring predictability in detailing and fabrication.Access to its exact geometric and statical properties is essential for 3D modeling and structural verification.

Geometry: This rectangular/square hollow section is defined by a depth of 200 mm, a width of 120 mm, and a uniform wall thickness of 5 mm. With a cross-sectional area of 3035.619449 mm² and a linear mass of 23.82961267 kg/m, the RHS 200x120/5 offers a distinct stiffness-to-weight ratio for both column (axial) and beam applications.

Section properties: For design of bending, the major and minor axis properties dictate the member's structural capacity. The strong-axis moment of inertia (Iy) of 16490000 mm⁴ governs major deflection and serviceability limits. To calculate the ultimate bending resistance, engineers may utilize the strong-axis plastic section modulus of 200900 mm³. For lateral stability and column buckling verifications, the weak-axis moment of inertia (Iz) provides 7501000 mm⁴ of lateral stiffness.

Advanced analysis: For complex load cases, the RHS 200x120/5 provides a y-axis shear area (at strong bending axis) of 1138.357293 mm² for web shear verification and a torsion constant of 16520000 mm⁴ for calculating rotational twist under eccentric loading.

Monthly Eurocode engineering digest

Stay ahead of Eurocode 3 & structural design updates

Get practical Eurocode verification guides, new calculator releases (like automated RHS 200x120/5 checks), and National Annex insights delivered once a month. Zero spam.